Update time: 23-02-14    Views: 1174

Zibo Onlyzone water treatment Technology Co., LTD

Test report




Sample No.: 20210708-01




Sample name: bath water purifier + ZONE filter material (3-4mm calcium sulphite ball)




Test items: residual chlorine removal rate of water supply test






Test condition:




1. Test water source: tap water (residual chlorine concentration2.5±0.2mg/L)




2. Product filling quantity: 40g




3. Product filling height: 7cm




4. Test flow rate:5L/min






Test method:




1、 Test the filter life of tap water and record the residual chlorine concentration at the inlet and outlet water.



Table 1: Test Table of residual chlorine concentration in and out of water

Water

L

Test the flow rate

Removal rate of residual chlorine

mg / L before filtration

mg / L after filtration

removal rate%

80L

5L/mi n

2.5

1.45

42%

250L

2.5

1.625

35%

420L

2.5

1.45

42%

590L

2.5

1.7

32%

760L

2.5

1.6

36%

930L

2.5

1.7

32%

1100L

2.5

1.75

30%



By Zhao from Onlyzone,a manufacturer of water treatment bio ceramic ball filter media in China.







Related News

Infuse Vitality into Pure Water: Precision Mineralization with ZONE  Calcium Ion Ceramic Balls

Infuse Vitality into Pure Water: Precision Mineralization wi

Chlorine removal principle of calcium sulfite ball

Chlorine removal principle of calcium sulfite ball

ZONE Composite carbon rod series filter material

ZONE Composite carbon rod series filter material

ZONE's active water filter material

ZONE's active water filter material

Zinc mineralized ceramic balls

Zinc mineralized ceramic balls

180 commonly used terminology for water treatment(Circulating water treatment)

180 commonly used terminology for water treatment(Circulatin

Product Categories

  • Calcium Sulfite Dechlorination Media
  • ORP Antioxidant Hydrogen Media
  • Alkaline Water Media
  • Fluoride Removal Media
  • Antibacterial Water Media
  • Mineral Water Media
  • Actived Water Media
  • Purified Water Media
  • KDF Media
  • Descaling Media
  • Condensate PH Neutralizer Media
  • Functional ceramic ball
  • Calcium Sulfite Dechlorination Media
  • ORP Antioxidant Hydrogen Media
  • Alkaline Water Media
  • Fluoride Removal Media
  • Antibacterial Water Media
  • Mineral Water Media
  • Actived Water Media
  • Purified Water Media
  • KDF Media
  • Descaling Media
  • Condensate PH Neutralizer Media
  • Functional ceramic ball

Links

Google.comBaidu.com

ABOUT US

  • Company profile
  • R&D ability
  • Quality control
  • Service
  • Our calculation program

PRODUCTS

  • Calcium Sulfite Dechlorination Media
  • ORP Antioxidant Hydrogen Media
  • Fluoride Removal Media
  • Alkaline Water Media
  • Antibacterial Water Media
  • Mineral Water Media
  • Actived Water Media
  • Purified Water Media
  • KDF Media
  • Descaling Media
  • Condensate PH Neutralizer Media
  • Functional ceramic ball

FEEDBACK

CONTACT US

8615615531918

joy@onlyzone.cn

Building 25-1, 333 Sanying Road, Zibo City, Shandong Province, China

Copyright © 2013-2022 Zibo Onlyzone Water Treatment Technology Co.,Ltd All Rights Reserved.

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry
Inquiry Us Now !
Inquiry Us Now !