Zone negative ion ceramic balls test report
Update time: 23-02-16 Views: 1279
Zibo Onlyzone water treatment Technology Co., Ltd.
Test Report
Sample number:20210721-01
Sample name: Filter kettle + zone filter material (1-2mmNegative Ion ceramic ball)
Test item: ph value, Tds value, magnesium ion dissolution
Test Conditions:
1. Water source: RO water (PH: 6.5, TDS: 10)
2. Filling quantity: 300g
3. Filling height: 10cm
4. Flow rate: 0.13L/min
Test Methods:
1. Test the service life of the filter element, record the ph value, tds value, and magnesium ion dissolution of the effluent
Table 1:ph value, tds value, magnesium ion dissolution of effluent
|
Water/L |
Influent PH value |
Effluent PH value |
Influent TDS mg/L |
Effluent TDS mg/L |
Magnesium ion Concentration mg/L |
|
0L |
6.5
|
/ |
10 |
10 |
0.0 |
|
6L |
9.5 |
30 |
4.6 |
||
|
12L |
9 |
25 |
3.7 |
||
|
36L |
8.8 |
24 |
3.7 |
||
|
54L |
7.6 |
20 |
2.76 |
||
|
72LL |
7.8 |
20 |
2.76 |
||
|
90L |
7.8 |
20 |
2.3 |
||
|
108L |
7.6 |
20 |
2.07 |
||
|
126L |
7.6 |
20 |
2.3 |
||
|
144L |
7.4 |
20 |
2.3 |
||
|
162L |
7.4 |
20 |
2.07 |
||
|
180L |
7.4 |
20 |
2.07 |
||
|
216L |
7.4 |
20 |
2.07 |
By Zhao from Onlyzone,a manufacturer of water treatment bio ceramic ball filter media in China.