Description
Product Description
Activated aluminum-based ball is a porous and highly dispersed composite solid material. Its rich specific surface area can quickly absorb fluoride ions and fluoride in water and form a stable fluorine complex, so as to achieve the effect of Fluoride Removal.
Product Parameters
Measure the fluoride ion concentration at 2 hours, record the value and replace with the same amount of fluorine solution with the same concentration. Repeat the test.
Number of Water Changes |
Raw Water |
After Filtration |
Removal Rate |
1 |
1.5 (mg/L) |
0 (mg/L) |
100% |
2 |
1.5 (mg/L) |
0 (mg/L) |
100% |
3 |
1.5 (mg/L) |
0 (mg/L) |
100% |
4 |
1.5 (mg/L) |
0 (mg/L) |
100% |
5 |
1.5 (mg/L) |
0.2 (mg/L) |
86.6% |
6 |
1.5 (mg/L) |
0.3 (mg/L) |
80.0% |
7 |
1.5 (mg/L) |
0.3 (mg/L) |
80.0% |
8 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
9 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
10 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
11 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
12 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
13 |
1.5 (mg/L) |
0.5 (mg/L) |
66.6% |
14 |
1.5 (mg/L) |
0.7 (mg/L) |
53.3% |
15 |
1.5 (mg/L) |
0.7 (mg/L) |
53.3% |
16 |
1.5 (mg/L) |
0.7 (mg/L) |
53.3% |

Product experiment
Application Scenarios
Widely used in purifiers water purifiers and filter elements
Test report
Safety inspection report
Zone Corp owns 2 roller kiln production lines for manufacturing bio ceramic balls with 16000 tons manufacturing capacity per year.
OEM package could be provided as your request.